ADDITIONAL THERMOSTAT
N.B. : Installation must be performed by an authorised technician
It is possible to thermostat a room adjacent to the room where the stove is positioned: just connect a thermostat following
the procedure described in the next point (it is recommended to position the optional mechanical thermostat at a height of
1.50m from the ground). Stove functioning with the external thermostat connected in the STBY clamp can be dierent on the
basis of the activation or deactivation of the STBY function.
The STBY clamp leaves the factory jumpered, therefore it is always with closed contact (on request).
ADDITIONAL THERMOSTAT FUNCTIONING WITH STBY ACTIVE
When the STBY function is activated, the LED ashes. When the contact or external thermostat is not satised (open
contact/temperature reached), the stove will switch o. As soon as the contact or external thermostat passes to the "not
satised" status (closed contact/temperature to reach) it will re-ignite.
Note: stove functioning depends on the temperature of the water inside the same and relative factory restrictions set.
If stove is in H OFF mode (water temperature reached), any additional contact or thermostat request will be ignored.
ADDITIONAL THERMOSTAT OPERATION WITH DEACTIVATED STBY
When the STBY function is deactivated, the LED is xed.
When the contact or external thermostat is not satised (open contact/temperature reached), the stove will go to minimum.
As soon as the contact or external thermostat passes to the "not satised" status (closed contact/temperature to reach) the
stove will start to work again at the pre-set power.
Note: stove functioning depends on the temperature of the water inside the same and relative factory restrictions set.
If stove is in H OFF mode (water temperature reached), any additional contact or thermostat request will be ignored.
ADDITIONAL THERMOSTAT INSTALLATION
Switch the appliance o using the master switch positioned on the rear of the stove.
Remove the plug from the socket.
Refer to the electrical layout to connect the two thermostat cables onto the relative clamps positioned don the rear
of the machine, one is red and the other black (STBY clamp). Every model can have a dierent position of the relative
clamps in the rear of the machine. The image is given as an example.
The STBY and AUX
clamps, found at the
back of the stove
(except for the Elisir
Model), can be noted
in the diagram at the
side
Follow the instructions
described below for
the connection to the
STBY and AUX clamps.
Remove the right
panel
Follow the instructions
described below for
the connection to the
STBY and AUX clamps.
Remove the right
panel
2272575
A
U
X
I2 GND
Pass the STBY and
AUX wiring through
the indicated cable
gland
J
FOR STANDBY ACTIVATION, REFER TO THE "USER MENU" CHAPTER