Extraflame Comfort Plus User Manual Page 29

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 28
29
ROOM THERMOSTAT
Chapter 6 Chapter 6
ROOM THERMOSTAT
DIGITAL THERMOSTAT AS PER STANDARD
The appliance can control the room temperature using a digital thermostat, which can lower the heating
power to minimum when a pre-set temperature is reached.
When the stove is started and has entered normal functioning mode, display D1 will show a number (e.g. 1.
21°C); this value indicates the room temperature.
Use buttons 2 or 3 to enter the thermostat setting and the display will show a  ashing word that alternates 2.
at every impulse with SET and the temperature to be set; by pressing 2 the value decreases and by
pressing 3 it increases.
Let “3. SET disappear from the display.
Adjust the desired heating power using buttons 4 and 5.4.
When the appliance reaches the temperatures set it automatically goes to a minimum functioning mode
and the relative luminous indicator switches-o in display D1.
If digital thermostat functioning thermostat is to be excluded, use button 3, to take the temperature to
maximum until HOT appears in display D1.
The same functions can be obtained using the remote control.
MECHANICAL THERMOSTAT OPTIONAL
N.B. :Installation must be performed by an authorised technician
It is possible to thermostat a room adjacent to the room where the stove is positioned: just connect a
mechanical thermostat (boiler type) following the procedure described in the next point (it is recommended
to position the optional mechanical thermostat at a height of 1.50m from the ground).
MECHANICAL THERMOSTAT INSTALLATION OPTIONAL
N.B. : Installation must be performed by an authorised technician
Switch the appliance o using the master switch positioned on the rear of the stove.1.
Remove the plug from the socket.2.
Refer to the wiring diagram to connect the two thermostat cables onto the relative clamps positioned 3.
don the rear of the machine< one is red and the other black.
MECHANICAL THERMOSTAT FUNCTIONING IN STDBY MODE TO ALSO BE USED
FOR TELEPHONIC ACTUATOR
The Stdby function is also used to further reduce fuel consumption by switching the stove o when the
desired temperature is reached. On the contrary, if the temperature drops, the stove automatically switches
back on, going to normal working conditions.
Set the desired heating power using buttons 4 and 5.1.
Using button 2, take the room temperature to minimum until 2. LOU appears in display D1 with SET
ashing.
At this point until 3. SET with LOU continues to  ash, press key 1 for three seconds and STBY will appear
in the display. The energy saving function is now activated.
At this point the external thermostat will control stove functioning in the following way:
Closed contact thermostat D the stove switches on and works at the set power, showing T ON on
display D1.