PRODUCT DISPLAY TABLES
40
Chapter 9
ALARMS
Signals
Reason Solution
Display
Indicates the presence of an alarm
It is on in the presence of one of the alarms described below
and is accompanied by the relative signal in display D1, which
identi es the cause. To reset the alarm, just hold key 1 down
for 3 seconds when the stove is completely cold.
FUM FAIL
Fault correlated to the  ue exhaust
motor.
The restoration operations must be carried out by an
authorised technician.
FUMI TC Fault correlated to the  ue probe
The restoration operations must be carried out by an
authorised technician.
HIGH TEMP Excessive pellet feed.
Adjust pellet  ow (see Pellet feed adjustment”).
Other restoration operations must be carried out by an
authorised technician.
DEPR FAIL
The door is not closed correctly.
The ash drawer is not closed
correctly.
The depression sensor is faulty.
The combustion chamber is dirty.
The  ue exhaust pipe is blocked.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the  ue pipe and the combustion
chamber.
Other restoration operations must be carried out by an
authorised technician.
NO ACC
The pellet feed-box is empty.
Pellet feed calibration in adequate.
Check for the presence of pellets in the feed-box.
Adjust pellet  ow (see Pellet feed adjustment”).
Check the procedures described in the “Ignition chapter.
Other restoration operations must be carried out by an
authorised technician.
NO ACC
BLAC OUT
No current during the ignition phase
Take the stove to o conditions using key 1 and repeat the
procedure described in the Ignition chapter.
Other restoration operations must be carried out by an
authorised technician.
NO PELL
The pellet feed-box is empty.
No pellet feed.
The motor reducer does not feed
pellets.
Check for the presence of pellets in the feed-box.
Adjust pellet  ow (see Pellet feed adjustment”).
Other restoration operations must be carried out by an
authorised technician.
ATTE +
ALLARME
Attempt to release the alarm with
stove still in cooling mode
Every time the stove displays one of the alarms listed above it
will switch-o automatically.
The stove will block any release attempt during this phase,
showing the alarm itself and ATTE alternately on the display.
The alarm can only be released using button 1 when it switch-
o has been completed.